Buy From China DC Lightning Arrestor Solar Surge Protection Device

  • Model NO.: FV20C/3-800 PV
  • Installation: Parallel Arrester
  • Size: Small
  • Certification: ROHS, ISO9001, CE
  • Color: Gray
  • Speed: <25ns
  • No. of Poles: 3 Poles
  • Uc: 825V DC
  • Housing material: UL94V0
  • Trademark: FATECH, OEM is welcome
  • Specification: CE
  • HS Code: 85363000
  • Type: Power Source Arrester
  • Application: AC/DC System
  • Operation Voltage: Low Voltage
  • Brand: FATECH
  • Protection Mode: L+-PE, L- - PE
  • Function: Surge Protection for PV System in DC Side
  • OEM&ODM: Welcome
  • Protection level: Class C protection
  • Imax: 40ka
  • Transport Package: 1 PC Surge Arrester in One Inner Box
  • Origin: China
DC surge protection device FV20C/3-800PV is for photovoltaic (PV) solar protection 825V DC, Imax 40kA, 3poles.

1. DC surge protection device for photovoltaic system Characteristic FV20C/3-800PV

-DC surge protection device specially used for photovoltaic system 800Vdc. 
-The core parts are metal oxide vristor components with high discharge capacity. 
-With Reliable control thanks to Thermo Dynamic Control disconnector. 
-With remote signaling contact for control device. 
-Fault indication via red mark in the inspection window.

2. Features of photovoltaic DC surge protection device FV20C/3-800PV:

There is a thermal cutoff member inside the photovoltaic DC surge arrestor, when the protector is over-current or over-voltage and the puncture is nonseviceable, the thermal cutoff member will automatically separate from the photovoltaic DC surge protector from the electrical network, and the indication window will turn red from green.

3. APPLICATION of DC surge protection device FV20C/3-800PV
Solar Panel, Photovoltaic (PV) System.

4. Certificate of the DC surge protection device
CE-DC-SPD

We also can supply DC surge protective device for photovoltaic (PV) system protection 1000VDC, surge protective device with Imax=60kA, 150kA. And type B lightning protective device with spark gap.

If you are interested in, please feel free contact to me!
  Model No.: FV20C/3-800PV      
  Max. continuous DC voltage[(L+/L-)-> PE]/ [L+-> L-]   Uc pv   V 825
  Requirement class to DIN EN 61643-1: 2005       Class C
  Nominal Discharge current(8/20μ s)   In   kA 20
  Max. discharge current (8/20μ s)   Imax   kA 40
  Voltage protection level (at In) [(L+/L-)-> PE]/ [L+-> L-]   Up   kV  <=3.2
  Response time   tA   ns  25
  Operation temperature range        -40 ~ +85degree
  Degree of protection       IP20
  Remote control contacts     NO

Socket

Transformer Electric Energy Meter Co., Ltd. , http://www.nswatermeter.com